Dual Application for Cooling Tower

Plastic cooling tower air stripper
Plastic cooling tower assembly
Courtesy Delta Cooling Towers
Cooling towers are readily identified by their ubiquitous presence in large commercial cooling systems. They are an effective means of rejecting heat from from a centralized liquid system. The general operating principle of a cooling tower involves a thermal and mass transfer from the cooling water to the surrounding air. The water is distributed by a number of means throughout the cooling tower fill, drastically expanding the surface area of the water. Air from the surrounding atmosphere is moved across the water surface. Assuming that the air is within the performance range of the cooling tower, the resulting evaporation of a portion of the water cools the liquid water remaining behind.

There are other applications for cooling towers, and Delta Cooling Towers, Inc., described one in a March 2017 news post. The application centered around a municipality with two challenges in providing potable water to residents. The water was being sourced from very deep wells and, without treatment, had an unacceptably high delivery temperature. Additionally, the sourced groundwater exhibited unacceptable levels of radon and hydrogen sulfide, naturally occurring gaseous contaminants that required level reductions to render the water suitable for human consumption and use.

Air strippers, equipment that aerates the water, are a common means of reducing the gaseous contaminant levels. In this case, though, there was the additional challenge of reducing the water temperature. All needed to be accomplished at process flow rates commensurate with the size of the municipal water demand.
A solution that solved both issues arose with the use of a cooling tower selected to provide sufficient aeration for gaseous contaminant reduction and cooling of the water to acceptable levels.
You can access the entire case history by reaching out to a product specialist, with whom you should share your own liquid processing challenges. Combining your process knowledge and experience with the product application expertise of knowledgeable professionals will produce effective solutions.

Friday, April 21, 2017

Vibration Dampening Improves Pressure Gauge Reading



Bourdon tube pressure gauges can exhibit rapidly oscillating indicators when subjected to pulsations from the measured line. The fast moving pointer on the dial face makes it impossible for an observer to obtain an accurate reading from the gauge. One solution has been to fill the case with a viscous liquid that served to dampen the vibration. While this is generally effective, it does create an additional potential maintenance burden related to the liquid.

A better solution is a dry gauge with a suitable means of dampening pointer oscillations that rivals that of liquid filled gauges. Winters Instrument, a manufacturer of industrial instrumentation on a global scale, offers a range of pressure gauges with their StabilZR™ dampened movement that provides liquid filled performance in a dry gauge.

The short video included with this post compares a standard dry gauge, liquid filled, and StabilZR™ versions. You can see the performance difference. Learn more about the StabilZR™ pressure gauges by sharing your process instrumentation challenges with application experts, combining your own process knowledge and experience with their product application expertise to develop effective solutions.


Tuesday, April 11, 2017

High Visibility Process Gauges Deliver Improved Readability in Low Light Conditions



Process gauges can sometimes, by necessity, be located in areas with low lighting or other conditions that do not promote easy viewing and reading of their dial face. Winters Instruments, manufacturer of a range of industrial instrumentation including dial face gauges, has released their WinBRIGHT high visibility pressure gauge dials. The new gauge dials provide either a highly reflective background color or glow in the dark option for the company's offering of pressure gauges in the 4" through 6" diameter range.

The video provides a quick overview of the new offering. Considering these gauges for installation in existing or new processes can bring better visibility to operators and technicians reading process gauges. More information is available from instrumentation specialists, with whom you should share your process measurement challenges and requirements. Combining your own experience and process knowledge with their product application expertise will yield a positive solution.

Wednesday, April 5, 2017

Closed Loop Cooling - Alternative Setup Delivers Benefits

Industrial processing often requires the transfer of heat, sometimes into the process, sometimes out of the process. External heat sources are often steam, hot water, or electric heaters. There are also instances where processing machinery either adds heat to the process or requires heat removal (cooling) in order to maintain proper function. If the heat source can accommodate a flowing liquid to provide removal of excess heat, it is a candidate for a closed loop cooling system.

One schematic for a closed loop cooling circuit would show the heat source connected to the piping system, with a pump for circulation and a finned coil located outdoors. The pump moves the heat transfer liquid through the hot area where heat moves from the process to the flowing liquid. The heated liquid continues to flow through the piping system to the finned coil, located outdoors. A fan moves air across the coil to provide heat transfer. The finned coil size would need to be comparatively large, since only sensible cooling using the forced air is employed. The fan capacity would be commensurate with the coil size and the circulating pump rating would be in line with the fluid moving requirements of the system. While this design is fairly simple, there may be a more efficient way to accomplish the heat transfer and deliver what may be beneficial additional features.

Consider a different schematic for the same application. This alternate design employs a closed loop cooling circuit for the heat source, but utilizes a different means of rejecting the heat from the closed loop to the outside air. A plate and frame heat exchanger transfers heat from the closed cooling loop to an open loop circuit that circulates through a cooling tower located outdoors. This scenario maintains the closed loop nature of the equipment cooling circuit, preventing entry of particulates or dissolved gases into the cooling fluid circulating through the process or machinery. Here is what the schematic looks like, courtesy of Delta Cooling Towers .
closed loop cooling system schematic with cooling tower
Closed loop cooling of process heat source using plat and frame heat exchanger and induced draft cooling tower
Courtesy Delta Cooling Towers
The cooling tower offers far greater efficiency than the fan and coil arrangement in the first design. Employing a plastic cooling tower will drastically reduce the life cycle cost over a galvanized steel model and the cooling tower will occupy significantly less space and require less costly support structure than the larger fan and coil arrangement. Total horsepower requirements for the system are reduced. The closed loop will not require any chemical additions for freeze protection because it no longer extends outdoors. This system also provides an element of flexibility, with expansion of the plate and frame heat exchanger a possibility. Cooling tower capacity is also expandable and available for other uses throughout the facility.

There are more details provided in the datasheet included below. Share your heat transfer and cooling challenges with application experts and explore various options. The combination of your process knowledge and experience with their product application expertise will produce an effective solution.