Providing problem solving and educational information for the flow control, industrial valve, heat exchanger and cooling tower market. Have a question about industrial controls, valves, heat exchangers or cooling towers? Give us a call at (303) 232-4100. Covering the markets of Colorado, Utah, Wyoming, New Mexico, Montana, Arizona, Nevada, Idaho, and the western Dakotas.| www.mnteng.com
Happy Holidays from Mountain States Engineering and Controls
From all of us at Mountain States Engineering and Controls, we wish our customers, partners and vendors a safe and happy holiday season and a wonderful 2019!
Mitigating Legionnaires Risk with Anti-Microbial Cooling Towers
![]() |
Anti-Microbial Cooling Tower (Delta Cooling Towers, Inc.) |
Causes:
- Poor water flow and areas where water is stagnant, common to cooling tower designs with a large flat bottom basin, which will have stagnant water in the corners.
- pH between 5.0 and 8.5, water temperatures between 68°F and 122°
- Sediment that promote growth of commensal microflora
- Microorganisms including algae, flavobacteria, and Pseudomonas, which supply essential nutrients for Legionella growth or harbor the organism
- Chemical Water Treatment: Oxidizing Biocides are recommended as the best mode of control. Warning: this type of biocide can be aggressive towards metal surfaces; specifically metal cooling towers.
- System Design & Engineering: No stagnant water, sloped basin, and/or basin sweeper system.
- Maintenance – Competent consistent water treatment and monitoring most important.
- According to the Center for Disease Control and Prevention, about 5,000 cases of Legionnaire’s disease are now reported each year in the United States.
Research in Legionella prevention led to conclusions that cooling towers with rounded basins and compounded with an antimicrobial resin significantly mitigated risk of harmful bacteria. Rounded towers improve circulation which inhibits growth, and the anti-microbial chemicals embedded into the tower’s HDPE material also helps to prevent the growth.
Resulting from the research, the Anti-Microbial Cooling Tower, was developed by Delta Cooling Towers, Inc. and is now available to greatly reduce the growth of Legionnaires bacteria, By incorporating an anti-microbial HDPE resin in the cooling tower shell, tower fill and drift eliminator, tests have confirmed efficacy against the growth and spread of Legionella.
For more information on Anti-Microbial Cooling Towers, visit this link.
To learn more about Anti-Microbial Cooling Towers right now, call Mountain States Engineering and Controls at 303-232-4100.